Intelligent Temperature Controller for Dry-Type Transformer

Product Details
Customization: Available
After-sales Service: Two Years
Warranty: Two Years
Still deciding? Get samples of US$ 140/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Minor Customization
The supplier provides minor customization services such as logo, graphic, package
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • Intelligent Temperature Controller for Dry-Type Transformer
  • Intelligent Temperature Controller for Dry-Type Transformer
  • Intelligent Temperature Controller for Dry-Type Transformer
  • Intelligent Temperature Controller for Dry-Type Transformer
  • Intelligent Temperature Controller for Dry-Type Transformer
  • Intelligent Temperature Controller for Dry-Type Transformer
Find Similar Products

Basic Info.

Model NO.
LON8000
Trademark
Linkelec
Origin
Made in China
Production Capacity
10000 Per Month

Product Description

Intelligent temperature controller for dry-type transformer
1.Product profile
The intelligent temperature controller for dry-type transformers consists of two circuits: a temperature monitoring system and an output control system. The temperature monitoring system uses a microcontroller as the central processing unit, combined with other circuits, to complete temperature measurement, display, and corresponding signal output. The output control system completes the control output and various status alarms and outputs of the cooling fan. In the temperature monitoring system, in order to achieve remote computer monitoring, the system uses RS-485 communication to transmit temperature data and parameters to a remote computer to form a distributed control system.
This product is a new generation controller designed specifically for the safe operation of dry-type transformers, which can simultaneously monitor the three-phase temperature of the dry-type transformer and control the fan. It has functions such as temperature over limit alarm, high temperature trip, sensor abnormality, and fan disconnection alarm, which can better ensure the safe and efficient operation of unmanned power supply systems. This product has the characteristics of strong environmental adaptability, high precision, small size, long service life, easy installation, and easy use.
The product is mainly used for temperature monitoring and fan control of dry-type transformers in power distribution systems. It can be widely used in distribution rooms with dry-type transformers, box type transformers, and other occasions.
Intelligent Temperature Controller for Dry-Type Transformer
Intelligent Temperature Controller for Dry-Type Transformer

2.Product specifications
performance parameters performance indicators
3-channel external temperature sensor probe temperature measurement Temperature range 0~200°C
Precision 1%FS
Operating power supply operating voltage range 220VAC(±20%)/50HZ(±4%)
Power consumption 6W
Communication interface type RS485
address range 1 to 247, where 0 is the broadcast address and 255 is the wildcard address
Baud rate 2400~9600bps
Statute Modbus-RTU
transmission distance 1KM
environmental conditions Operating Temperature -25ºC~+70ºC
Operating humidity 0~93%RH

3.Selection specifications
function module Serial number function point function point descriptions Intelligent temperature controller for dry-type transformers
LON8000
real-time measurements 1 Winding temperature measurement Up to 3 external temperature sensor probes can be accessed to measure 3 temperatures.
Temperature imbalance 2 Temperature imbalance Calculating the three-phase temperature imbalance, the
cooling fan control 3 control mode manually activating the fan
4 automatic fan activation
Cabinet door opening and closing monitoring 5 Cabinet door opening and closing monitoring Cabinet door opening and closing monitoring, monitoring of open door alarm, switching input.
Alarm 6 Over-temperature alarm When the temperature value monitored by the device can not be reduced under the cooling of the fan, and rises to the set point of "over-temperature alarm", the over-temperature alarm signal is activated, and the over-temperature indicator light is on, until the temperature drops to the "alarm return point" (the difference between the alarm point and the return difference), then the alarm signal is canceled and the indicator light goes out. When the temperature drops to the "alarm return point" (the difference between the alarm point and the return difference), the alarm signal will be lifted and the over-temperature indicator will go out.
7 High temperature trip alarm When the temperature value monitored by the device reaches the "over-temperature alarm point", it will not be effectively controlled and will rise to the set "high temperature trip action point", and after a delay, it will activate the "high temperature trip" signal, and the trip indicator will light. After a delay time, the "high temperature trip" signal will be activated and the trip indicator light will be on. And through the trip function to stop the operation of the equipment to prevent equipment damage.
8 Fault Alarm If the temperature sensor is abnormal (short-circuit or disconnection), the corresponding fault indicator lights up and the "Fault Alarm" relay operates. The output of the "Fault Alarm" relay is energized and closed.
event logging 9 SOE event logging Record the over-temperature alarm;
Three-phase temperature imbalance record;
The best-value record The maximum and minimum values are recorded
Communications 10 means of communication RS485
11 communication protocols Modbus-RTU
12 mailing address 1~247, 0 is the broadcast address,255 is the wildcard address
13 the communication baud rate 2400 bps,4800bps,9600bps
control parameter settings 14 temperature setting range 0~200°C
15 The return difference, the 5~20°C
16 Trip delay 1 to 60 seconds
control and signal output 17 fan control Active contact output (normally open) 16A/220VAC for direct drive of single-phase fans
18 Over-temperature warning Passive contact output (normally open) 5A/220VAC, 10A/28VDC
19 High-temperature tripping Passive contact output (normally open) 5A/220VAC, 10A/28VDC
20 Fault Alarm Passive contact output (normally open) 5A/220VAC, 10A/28VDC
Data zeroing 21 Data zeroing The stored data is completely erased
Note: "√" indicates that this function is standard, "○" indicates that this function is optional 

4.Product installation and schematic diagram
Intelligent Temperature Controller for Dry-Type Transformer
5.About our service           
*  We could provide 7* 24-hour phone call after-sales service. 
*  We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
*  Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.

6.Package and ship
Intelligent Temperature Controller for Dry-Type Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier