Data classification | Data item | Data subitem | Acquisition frequency |
Running class | voltage | Phase a voltage | On demand acquisition |
B phase voltage | |||
C phase voltage | |||
electric current | A phase current | ||
B phase current | |||
C phase current | |||
active power | Current total active power | ||
wattless power | Current total reactive power | ||
Power factor | Power factor | ||
Active power control ratio | Active power control ratio | ||
Reactive power control ratio | Reactive power control ratio | ||
DC side voltage | DC side voltage | ||
DC side current | DC side current | ||
State class | Inverter temperature | Inverter temperature | On demand acquisition |
Communication status | Communication status between distributed power access unit and inverter | ||
Inverter operation state | On-off state of inverter | ||
Inverter fault state | malfunction | ||
Remote operation and maintenance | Remote operation and maintenance | ||
Statistical class | Total grid-connected operation time | Total grid-connected operation time | On demand acquisition |
Daily power generation | Daily power generation | ||
annual energy output | annual energy output | ||
parameter | Basic information of inverter/distributed power supply access unit | mailing address | On demand acquisition |
user account | |||
Number of virtual power plant | |||
Rated active power | |||
Maximum active power | |||
Maximum reactive power | |||
Maximum apparent power | |||
type of output | |||
control model | Active power control mode | On demand acquisition | |
Reactive power control mode | |||
Photovoltaic module data (kWp) | Installed capacity | ||
user type | Full/spontaneous surplus, energy storage and charging pile | ||
Adjustable and controllable | Adjustable and controllable | ||
Control class | Inverter control | Inverter switch | Active distribution |
Remote control enable | Remote control enable | Active distribution on demand (mode 1: group control; mode 2: single control (with address)) | |
Data freezing | Data freezing | ||
initialization | initialization | ||
Control mode | Active power setting value | ||
Active power percentage | |||
Reactive power setpoint | |||
Reactive power percentage | |||
Reactive power percentage regulation | |||
Power factor control |
test item | grade | experimental value | Test loop |
Voltage sag and short-time interruption | -- | 3000:1(60%),50:1,1:1 | complete built unit |
Power frequency magnetic field immunity | -- | 400 A/m | complete built unit |
Radiation immunity of radio frequency electromagnetic field | 3 | 10 V/m(80 MHz~1000 MHz) | complete built unit |
4 | 30 V/m(1.4 GHz~2 GHz) | complete built unit | |
Immunity to conducted disturbance induced by RF field | 3 | 10V (unmodulated) | Power supply circuit |
Electrostatic discharge immunity | 4 | 8kV, direct and indirect | shell |
Electrical fast transient immunity | 3 | 1.0kV (coupling) | Communication line |
4 | 4.0 kV | Power supply circuit | |
Surge immunity | 4 | 4.0 kV (common mode) | Power supply circuit |
2.0 kV (differential mode) | |||
Immunity of damped oscillation wave | 4 | 2.5 kV (common mode) | Power supply circuit |
1.25 kV (differential mode) | |||
Radio interference suppression | B | - | complete built unit |