Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Minor Customization
The supplier provides minor customization services such as logo, graphic, package
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • Low Voltage Line Protection Device
  • Low Voltage Line Protection Device
  • Low Voltage Line Protection Device
  • Low Voltage Line Protection Device
  • Low Voltage Line Protection Device
  • Low Voltage Line Protection Device
Find Similar Products

Basic Info.

Model NO.
LON531L
Trademark
Linkelec
Origin
Made in China
HS Code
90283012
Production Capacity
10000 Per Month

Product Description

Intelligent low-voltage line protection and measurement device
1.Product profile
The intelligent low-voltage protection and measurement device is a new generation of protection and measurement device developed by our company for various fault characteristics of low-voltage MCC circuit motors. It is suitable for AC380V and AC660V low-voltage systems and is mainly divided into LON531D low-voltage motor protection and measurement device and LON531L low-voltage line protection and measurement device. It is a low-voltage protection and measurement device with extremely high cost-effectiveness, stability and reliability, integrating relay protection, measurement, control, and communication. The protection measurement and control device collects data such as three-phase current, three-phase phase voltage, line voltage, grounding current, etc. These data are calculated and compared with various protection function setting information recorded by the device. When the protection action conditions are met, the relay output is driven to achieve reliable protection of the motor.
The intelligent low-voltage protection measurement and control device consists of two parts: the protection measurement and control device host and the MCT current transformer. It can achieve measurement function, protection function, motor start/stop control function, and remote communication function. Using RS485 communication function as an important means of remote management, supporting MODBUS-RTU communication protocol.
Low Voltage Line Protection Device
Low Voltage Line Protection Device
2.Product specifications
function point function point descriptions motor protection line protection
protection functions Initiate timeout protection -
overload protection, overcurrent blocking protection, short circuit protection -
Current imbalance protection
Voltage unbalance protection
phase failure protection -
ground fault synthesis computational protection
Leakage protection / ground fault real pick protection (need to be equipped with zero sequence current transformer / grounding current transformer)
(Either/or) (Either/or)
underload protection -
overflow fault (fault current exceeding the breaking capacity of the contactor) trips the circuit breaker -
Over-voltage protection, loss of voltage, under-voltage protection
frequency protection, under power factor protection, phase sequence protection -
Anti-Shake/Shake Restart
External interlocks
tE time protection -
Electrical current interruption protection (low voltage blocking overcurrent section) -
Current-limited quick disconnect protection (low voltage blocking overcurrent II) -
Overcurrent protection (three stages of overcurrent) -
Overload protection -
Spring not storing energy alarm -
PT disconnection alarm -
Temperature protection (PTC/NTC) -
Control loop disconnection alarm -
Negative sequence protection -
under power protection -
phase sequence protection -
inverse time overcurrent -
Three-stage fixed-time overcurrent -
inverse time zero sequence overcurrent -
three-segment time-limited zero-sequence overcurrent -
real-time measurements three-phase current, grounding current, three-phase current unbalance ratio
Leakage current/grounding actual pickup current
three-phase phase voltage, three-phase line voltage, frequency
power factor, active power, reactive power, active energy, reactive energy
zero sequence voltage, positive sequence voltage, negative sequence voltage -
Power quality (including 2nd~63rd harmonics, voltage-current unbalance rate, harmonic distortion rate)
line fault alarms loss of voltage, overvoltage, undervoltage, voltage imbalance, voltage reverse order, voltage transient rise/fall
Loss of current, overcurrent, current breakage, current imbalance, current reverse order
overload, phase failure, demand overrun
event logging Line Fault Alarm, DI Transposition, Closing and Opening Records, up to 100 records
Fault recording, up to 50 entries
Motor running hours, stopping hours, number of normal circuit breaker trips, number of fault trips
switching inputs With 8-channel DI, built-in power supply, external passive trunk node
Relay Output With 5-way DO, AC 250/10A; DC 30V/10A
analog output Optional 1-channel DC4~20mA analog variable output
digital communications 2 RS485 interfaces, support MODBUS-RTU protocol
undervoltage restart With the voltage detection function module, it can realize the short-time under and voltage loss restart function -
protection parameter settings All kinds of protection fixed value query, adjusting
system parameterization Parameterization of rated voltage, rated current, and communication address
LED indication start, run, alarm/action, stop
Online upgrade Support 485 communication mode upgrade
Note: "√" indicates that this function is standard, "○" indicates that this function is optional, and "-" indicates that this function is not available 

3.Selection specifications  
performance parameters performance indicators
accuracy class U,I : ±1%,P,Q,PF :±2%,F :±0.1HZ, 
active energy: level 2, reactive energy: level 2
Wiring method Three-phase, four-wire
Input Voltage Rated voltage 380V 660VAC
Frequency range  45~65Hz
Measuring range 10% ~ 120%Ue
Power consumption < 0.3VA
Input current Rated current 1A,2A,5A,6.3A,10A,25A,30A,50A,100A,200A,400A
overload capacity 2Ie (continuous); 10Ie (10s allowed); 40Ie (1s allowed)
Measuring range 10% ~ 200%Ie
Power consumption < 0.5VA
Leakage current Measuring range 10% ~ 100%Is
Measurement accuracy ±1%FS
Operating power supply operating voltage range AC /DC 85~264V
Power consumption <9W
analog output Output range 4ma ~ 20ma
maximum load capacity 500R
RTDs Temperature range 0.1K ~30K
Temperature measurement error ±2%FS
switching outputs output form mechanical contacts
Maximum switching voltage 250V AC,30VDC
Maximum switching current 10A
voltage withstand between contact and coil 2500Vac rms
switching inputs Input form   Active Wet Node Error ±20%
(External 220VAC, 220VDC, 110VDC)
Passive trunk node (internal 24VDC)
isolation voltage 2000Vac rms
485 interface interface form Half-Duplex, Optically Isolated
address range 1~247
communication protocols Modbus-RTU
the communication baud rate 2400~19200bps, default 9600bps
environmental conditions Operating Temperature  -20ºC~60ºC
storage temperature  -25ºC~70ºC
Operating humidity 0 to 85% non-condensing
Atmospheric pressure 86kPa~106kPa
Measurement performance electrical energy accuracy GB/T 17215.321-2021 Class A
mechanical properties Vibration GB/T 11287 severity class 1
Impact GB/T 14537 Severe Grade 1
Collision GB/T 14537 Severe Grade 1
electromagnetic compatibility performance Radio Frequency Electromagnetic Field Immunity Test  GB/T 17626.3-2016 severity level 3
Electrical fast transient pulse group test  GB/T 17626.4-2018 severity level 3
Attenuated oscillatory wave immunity test   GB/T 17626.12-2013 severity level 3
Surge immunity  GB/T 17626.5-2019 severity level 3
RF conducted immunity  GB/T 17626.6-2017 severity level 3
Radio interference  GB/T 17215.211-2021 Class B equipment
Work-frequency magnetic field interference degree   GB/T 17626.8-2006 severity level 3
electrical insulation properties insulation resistance GBT 13729-2019 , not less than 100MΩ
medium strength GB/T 13729-2019, Industrial frequency voltage 2.5kV, 1 min
Impulse voltage GB/T 13729-2019,1.2/50μs,5kV
4.Product installation and schematic diagram
Low Voltage Line Protection DeviceLow Voltage Line Protection Device
5.Solution
Low Voltage Line Protection Device

6.About our service           
*  We could provide 7* 24-hour phone call after-sales service. 
*  We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
*  Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.


7.Package and ship
Low Voltage Line Protection Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now