Customization: | Available |
---|---|
After-sales Service: | Two Years |
Warranty: | Two Years |
Still deciding? Get samples of US$ 90/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
performance points | performance indicators | |
Operating power supply | operating voltage range | AC 176~264V |
Power consumption | <2.5W,5VA | |
wireless communication interface | interface form | LORA interface |
communication protocols | Modbus-RTU | |
means of communication | Star-shaped | |
communication distance | Point-to-point communications with an open line of sight of 300 meters | |
number of mounts | 35 mountable | |
environmental conditions | Operating Temperature | -20ºC~70ºC |
storage temperature | -40ºC~70ºC | |
Operating humidity | 0 to 95% non-condensing | |
Atmospheric pressure | 86kPa~106kPa | |
mechanical properties | Vibration | GB/T 11287 severity class 1 |
Impact | GB/T 14537 Severe Grade 1 | |
Collision | GB/T 14537 Severe Grade 1 | |
electromagnetic compatibility performance | Radio Frequency Electromagnetic Field Immunity Test | GB/T 17626.3-2006 severity level 3 |
Electrical fast transient pulse group test | GB/T 17626.4-2008 Severity level 3 | |
Attenuated oscillatory wave immunity test | GB/T 17626.12-1998 Severe Grade 3 | |
Surge immunity | GB/T 17626.5-2008 Severity level 3 | |
RF conducted immunity | GB/T 17626.6-2008 Severity level 3 | |
Radio interference | GB/T 17215.211-2006 7.5.8 Class B equipment | |
Work-frequency magnetic field interference degree | GB/T 17626.8-2006 severity level 3 | |
electrical insulation properties | insulation resistance | GBT 13729-2002 , not less than 100MΩ |
medium strength | GB/T 13729-2002, Industrial frequency voltage 2kV, 1 min | |
Impulse voltage | GB/T 13729-2002,1.2/50μs,5kV |