performance parameter | Performance index | |
accuracy class | U, I: 0.2, P, Q, PF :0.5, F: 0.01 Hz, | |
Active energy: 0.5, reactive energy: 2. | ||
network | Three-phase four wire | |
input voltage | rated voltage | AC 3*220/380V |
frequency range | 45~65Hz | |
overload capacity | 1.2Un (continuous); 2Un (10s allowed) | |
measuring range | 5V~1.2Un | |
Power consumption | <=0.3VA per phase | |
incoming current | rated current | ≤100mA |
overload capacity | 1.2In (continuous); 20In (1s allowed) | |
measuring range | 0~1.2In, | |
Power consumption | <=0.2VA per phase | |
working power supply | Operating voltage range | AC/DC 85V~265V |
Power consumption | <=5VA | |
contact rating | AC250V/5A,DC30V/5A | |
Pulse output | 1-way power pulse output, optocoupler isolation. | |
communication interface | Interface form | RS485 and 4G communication |
protocol | Modbus-RTU,MQTT | |
environmental conditions | Working temperature | Working temperature range:-20ºC ~ 60ºC |
Working humidity range: ≤ 98% (40ºC 2ºC), without condensation. | ||
Atmospheric pressure range: 106kpa ~ 70kpa (0m ~ 4000m). | ||
storage temperature | -40ºC~70ºC | |
mechanical character | vibrate | GB/T 11287 severity level 1 |
lash | GB/T 14537 severity level 1 | |
collide | GB/T 14537 severity level 1 | |
Electromagnetic compatibility performance | Radio frequency electromagnetic field immunity test | GB/T 17626.3-2006 Severity Grade 3 |
Electrical fast transient test | GB/T 17626.4-2008 Severity Grade 4 | |
Attenuated oscillation wave immunity test | Severity grade 3-12-1998 | |
Electrostatic discharge test | GB/T 17626.2-2006 Severity Grade 4 | |
Surge immunity | GB/T 17626.5-2008 Severity Grade 4 | |
Radio frequency conduction immunity | GB/T 17626.6-2008 Severity Grade 3 | |
radio disturbance | GB/T 17215.211-2006 7.5.8 Class B Equipment | |
Interference degree of power frequency magnetic field | GB/T 17626.8-2006 Severity Grade 3 | |
Electrical insulation performance | insulance | GBT 13729-2002, not less than 100MΩ. |
dielectric strength | GB/T 13729-2002, power frequency voltage 2kV, 1 minute. | |
surging | GB/T 13729-2002,1.2/50μs,5kV | |
measure | Height * width * depth | 106mm*87mm*59mm |
functional module | serial number | Function point | Function point description | intelligence |
Ac watt-hour meter | ||||
LON813E-4G | ||||
auxiliary power supply | 1 | AC85~265V | √ | |
Real-time measurement | 2 | phase voltage | Phase voltage: Ua, Ub, Uc | √ |
3 | line voltage | Line voltage: Uab, Ubc, Uca | √ | |
4 | Voltage sequence component | Voltage sequence components: U1, U2, U0 | √ | |
5 | phase current | Phase current: Ia, Ib, Ic | √ | |
6 | Current sequence component | Current sequence components: I1, I2, I0 | √ | |
7 | active power | Active power: Pa, Pb, Pc, p. | √ | |
8 | wattless power | Reactive power: Qa, Qb, Qc and Q. | √ | |
9 | apparent power | Apparent power: Sa, Sb, Sc, s | √ | |
10 | Power factor | Power factor: Pfa, Pfb, Pfc, Pf | √ | |
11 | phase position | Voltage/current: ∠Ua, ∠Ub, ∠Uc, ∠Ia, ∠Ib, ∠Ic | √ | |
12 | frequency | System frequency: f | √ | |
Electricity measurement | 13 | Active power | Split-phase and combined-phase bidirectional active energy | √ |
14 | Reactive power | Split-phase and combined-phase bidirectional reactive power | √ | |
15 | Apparent electric degree | Split-phase and close-phase are in electric energy. | √ | |
remote signalling | 16 | Drive in and out | It has the status of remote communication in and out. | ○ |
17 | Fault alarm | With, overvoltage, overcurrent, voltage loss, fault alarm, etc. | √ | |
clock | 18 | clock | Accurate clock with hardware | √ |
in-out | 19 | Switch input | Up to 2 passive node switch inputs can be selected. | ○ |
20 | Switch output | Up to 2 switch outputs can be selected, and level/pulse mode is supported. | ○ | |
21 | Pulse output | With active energy pulse output port, used for accuracy detection of electric energy meter. | √ | |
communication interface | 22 | RS485 communication | Support RS485 communication and MODBUS-RTU protocol; | √ |
23 | wireless communication | Support 4G wireless communication, support IEC104 protocol and FTP upgrade. | √ | |
Note: "√" marks this function as standard, and "○" indicates that this function is optional. |